Phase controller
APC DPC10DPC05
본문
Features
- Power Supply Voltage : AC100V ~ AC240V
- Sensor Voltage : DC24V, 200mA
- Control Signal : COM and IN Terminal short (No-Voltage contact or TR)
- Bowl / Hopper Associated control
- Constant Amplitude : When install VS50, Detects weight can be changed automatically
Dimension
Item | Content | Remark | |
Model Name | DPC05 | ||
Environmental Specification | Working Temperature | 0 ~ 55℃ | |
Working Humidity | 10 ~ 90% | ||
Electrical Specification | Input Voltage | AC100V ~ 240V, 50HZ ~ 60HZ | Automatic |
Number of Phade | 1 | ||
Fuse Capacity | 5A | Internal Fuse | |
Radiator Temperature | Stop temperature at 70℃ or Over | *Output Stop *Auto Return |
|
Heater Overheating Abnormality | OH Display | ||
Output Specification | Control Method | Phase Control | |
Control Element | TRIAC | ||
Output Voltage | 0.0V ~ 200.0V | ||
Operation Specification | Operation Method | *RUN
/ STOP control with control signals *No output line open during RUN |
Sensor, Contact, TR |
Control Voltage | DC 24V, Rated Current 200mA | ||
Time Setting | 0.1 ~ 9.9sce | ||
Inter-Control | Bowl Feeder / Hopper Feeder | ||
Constant Amplitude | Installed Vibration sensor, Output voltage by Auto compensation | Automatic |